ASTM D6760 PDF

Crosshole Sonic Logging» ASTM D | ACI R. Crosshole Sonic Logging is the most accurate and reliable technique for assessing the integrity of . ASTM D (Ultrasonic Crosshole Testing).pdf – Download as PDF File .pdf ), Text File .txt) or read online. All the Controls products ASTM D standard. Enter now!.

Author: Kezuru Daijind
Country: Laos
Language: English (Spanish)
Genre: Education
Published (Last): 13 May 2017
Pages: 90
PDF File Size: 20.18 Mb
ePub File Size: 2.34 Mb
ISBN: 837-9-97939-131-3
Downloads: 53388
Price: Free* [*Free Regsitration Required]
Uploader: Zologul

Link to Active This link will always route to the current Active version of the standard. Active view current version of standard.

Historical Version s – view previous versions of standard. Plans, specifications, provisions, or combinations thereof prepared by a qualified engineer, and approved by the agency requiring the test smay provide additional requirements and procedures as needed to satisfy the objectives of a particular test program. No other units of measurement are included in this standard. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. This method can also be extended to diaphragm walls, barrettes, dams etc.

ASTM D, Test equipment Controls

Asym defects are detected, then further investigations should be made by excavation or coring the concrete as appropriate, or by other testing such as Test Method D6d760 or Dand measures taken to remediate the asgm if a defect is confirmed. The method does not give the exact type of defect for example, inclusion, honeycombing, lack of cement particles, etc.

  APPLIED PHARMACOLOGY BARDAL PDF

This method is most applicable when performed in tubes that are installed during construction. Since the generated waves travel through the concrete around the access duct, unless a flaw is massive enough and very near to the access duct it may not be detected by this method.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM D6760 – 16

The data are used to confirm adequate concrete quality or identify zones of poor quality. Reliable results depend on many factors; Practice D provides a means of evaluating some of those factors.

These notes and footnotes excluding those in tables and figures shall not be considered as requirements of the standard. Xstm to Active This link will always route to the current Active version of the standard. R6760 other units of measurement are included in this standard.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and aetm suitability of the equipment and facilities used.

The method does not give the exact type of flaw for example, inclusion, honeycombing, lack of cement particles, etc. Agencies that meet the criteria of Practice D are generally considered capable d67600 competent and objective testing and inspection. These notes and footnotes excluding those in tables and figures shall not be considered as requirements of the standard.

  BUDIDAYA JABON PDF

This method can also be extended to diaphragm walls, barrettes, dams etc. This test can assess to the integrity of the concrete mainly in the area bounded by the access ducts, which means typically inside the reinforcement cage.

Plans, specifications, provisions, or combinations thereof prepared by a qualified engineer, and approved by the agency requiring the test smay provide additional requirements and procedures as needed to satisfy the objectives of a particular test program.

This method is most applicable when performed in tubes that are installed during construction. Testing should therefore be performed as soon as practical in order to avoid debonding issues.

How one applies the results obtained using this standard is beyond its scope. The method is limited primarily to testing the concrete between the access ducts and thus gives little information about the concrete outside the reinforcement cage to which the access ducts are attached when the tubes are attached to the inside of the reinforcement cage.

How one applies the results obtained using this standard is v6760 its scope. Users of this standard are cautioned that compliance with Practice D does not in itself assure reliable results.