VIEW PRODUCTS BY CATEGORY. Serial Servers (4). 4 results You’ve selected: PortServer TS X PortServer® TS MEI Hardened Hardened, Rugged Serial. Buy Digi PortServer TS 4 MEI Device Server: Device Servers – ✓ FREE DELIVERY possible on eligible purchases. Buy Digi PortServer TS 4 port RS RJ – Electronics – Amazon. com ✓ FREE DELIVERY possible on eligible purchases.

Author: Doubar Nebar
Country: Belarus
Language: English (Spanish)
Genre: Music
Published (Last): 28 July 2004
Pages: 16
PDF File Size: 10.64 Mb
ePub File Size: 2.97 Mb
ISBN: 355-6-58163-277-5
Downloads: 81619
Price: Free* [*Free Regsitration Required]
Uploader: Dale

I am a little confused on how one static IP knows which port to go to for requesting the slaves information. Available in 1, 2, or 4-port models, these serial servers combine the inherent benefits of data networking with proven asynchronous connectivity.

Is their a module for rs connection to a serial port? I was told we need to request the Comm port but we currently do Modbus TCP on all of our applications.

Any clues as to why Ignition gets null values? Rapid Proof-of-Concept Project Planning. Industrial Precision Agriculture Manufacturing Automation. PortServer TS serial servers offer RS serial port expansion, making it easy to connect any serial device to your network.

Portsrever their and OPC connections or module for connecting to a serial port to request the information? Enabling wireless 44 aboard the space station. I can get the traffic to go out but no traffic to come in.

  HERBALIFE TOXICIDAD HEPATICA PDF

PortServer TS4 MEI Device Server

I usually use TCP sockets mode when using the digi portserver. Patented encryption feature of RealPort Read. I am not familiar with the Ignition modbus driver, but it looks like they have 2 modes, modbus tcp and modbus rtu over tcp tcp sockets in the digi.

In that mode each serial port has a separate tcp port number to use, and then you would use the plc’s unique rtu address to differentiate between the plc’s. Is your tool using unit ID 1 by default? We digl running 7. I either have to figure out why the Igntion Poetserver Driver is causing problems or buy kepwares modbus driver if it will work. Contact a Digi expert and get started today! Addressing was all correct for RTU. The device is connected on Ignition and when I log into the Digi Portserver it says all communications are good, but when i try and pull in tags they are Null.

From there you can move back to the digi and figure out where the trouble is. Failure Analysis and Mitigation.

Wireless Design Services World class design and development. I installed Modbus Poll tool on our server and put in the IP and port and requested 10 registers and they came back instantly.

  CIPRIANO GOMEZ LARA DERECHO PROCESAL CIVIL PDF

Digi Smart Solutions Temperature and task management. Digi XBee Ecosystem Explore and create wireless connectivity.

Easy Serial-to-Ethernet Connectivity – Digi International

They deliver powerful, yet simple Ethernet connectivity for all your serial devices. Technical Support Services Support services to meet any portserverr. Ignition assumes unit ID 0 unless specified otherwise.

The first thing I would do is to use a software like modbus poll to make sure I can grab modbus data from the PLC’s with your laptop connected to the port on the freewave.

– PortServer TS 4 – Digi International

I am trying to reach slave Radios on PLC’s in the field with ignition. Remote Device Manager Monitor and maintain deployments.

Redundancy in Serial-to-Ethernet Communications Read. Expert Support Upgrade for premium services Professional Services Development, consulting and training Compare Support Services Digi base, expert or professional services Support Tools Drivers, documentation and firmware. Digi Smart Solutions is now SmartSense. I have been on the phone with Digi tech support and they are not much help.